1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for the colony, tx

Rated 5.0 out of 5 stars based on 12 customer reviews

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

They were great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Survey

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

As always great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Very efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always taken care of

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional Service

Technician did an excellent job 👏

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for the colony, tx

Mike  S.

Mike S. Job Checkin

Tested all components all measured within ratings and specs. Refrigerant level is normal. Washed and cleaned condenser. Changed filter. Recommend duct cleaning lvl1


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival systems were running and cooling producing 18+ degree deltas. Indoor units had clean coils and drain lines but dirty blowers. Supply plenum for upstairs system had large spots of biological growth. Outdoor units passed all electrical testing but were overamping on start up. I recommended compressor saver kits to address this and to reduce wear and tear on the compressor. I recommended an April aire upgrade kit to prevent further dust bypass and I recommended iaq 200 uv systems to prevent further biological growth and improve air quality.


Daniel S.

Daniel S. Job Checkin

Arrived for STU Recommend refurbishing, IAQ 3000, blower clean and coil clean. Customer would like to have a comfort advisor out on May 2/2024 @12-3


Mike  S.

Mike S. Job Checkin

Tested all components all measured within ratings and specs. Refrigerant level is normal. Washed and cleaned condenser. Customer changes filter himself on the 1st every month.


Brock S.

Brock S. Job Checkin

Arrived for Eval of upstairs system. Asked home owners if they wanted their down stairs to be looked at and they said yes. All components were working and in tolerance Recommended IAQ 200, 1000, Blower clean, Coil clean, panstrip for both units. Surge protection for whole house and membership. Relayed Information to customer and told them that their upstairs system was working. Customer wanted to think about recommendations.


Blake  B.

Blake B. Job Checkin

Tech arrived at a tune-up/ IAQ estimate. Upon inspection, the capacitor was out of tolerance. The condenser coils were hosed off to assist with air flow across the coils. The refrigerant was within range. The filter was dirty. The blower area was dirty and there was growth present in the system. There was ductwork that was not sealed properly in the attic. Tape was applied to these areas. The Delta was within range. The customer was informed of recommendations today. He is interested in the IAQ 1000 Filter, 200 UVC System / Air Cleaner and Level 2 Duct Cleaning. He will speak with his wife and will call us back. He would like a follow up next week if we haven't heard from him by then. The system was functioning upon departure.


Blake  B.

Blake B. Job Checkin

Tech arrived at a complimentary tuneup. Upon inspection, the capacitor was out of tolerance. The condenser coils were hosed off to assist with air flow across the coils. The refrigerant appeared to be overcharged and the TXV was not functioning. The blower area was dirty. The customer was provided with duct cleaning estimates upon request. The customer was informed of recommendations today. He will speak with his wife and will call back in. The tech will follow up at a later date. The system was functioning upon departure.


Tyler S.

Tyler S. Job Checkin

04/06/24 Tyler - waterheater is new and was expecting an AC check up.


Tyler L.

Tyler L. Job Checkin

I was told that felt very hard and was causing issues replacement should fix that I also was told of an issue where if he starts up his vacuum a few of the lights dim in the house that one would require a minor diagnostic and I have made an estimate and sent it to the email on phone


Blake  B.

Blake B. Job Checkin

Techa arrived at a tune-up. The capacitor was within specs. The contactor was in working condition. The condenser coils were hosed off to assist with air flow across the coils. The filter was relatively clean. The drain was clear and bleach was poured. The customer was informed of recommendations today. He decided to move forward with adding the membership. He would like to think about which #IAQ products he would like to install and would like a call back. The tech will follow up. The system was functioning upon departure.


Blake  B.

Blake B. Job Checkin

Tech arrived at a tune-up. Upon inspection the system has a low side sat temp around 32 degrees and the pipes were freezing. The Superheat was 1 degrees indicating a possible overcharge. There may be a restriction in the lines. The contactor was scorched. The ductwork and blower area was very dirty. The furnace control board had dust on it. The heating system reached complete ignition. The flame sensor was scorched. The filter was dirty. The customer was informed of recommendations today. He is not able to move forward with repairs or replacement at this time but decided to add a Home Budget Membership. He would like the plumbing evaluation to be performed as soon as possible as he is having lighting issues. The system was left in the off position to avoid further damages. He will call back in at the end of summer to approach further system needs.


colby.finch@acgenius.com

colby.finch@acgenius.com Job Checkin

On arrival both systems were running and heating producing a 20 degree delta. The indoor unit had clear drain lines and a clean blower and coil. The outdoor units passed all electrical testing and were running when I left.


Tyler S.

Tyler S. Job Checkin

Quoted on tankless and electrical tank waterheaters. Insist on having tank installed on risers. Water supplies will have to be moved up in order to reach. And have an air gap with the T&P drain line.


Brock S.

Brock S. Job Checkin

After arrival I was able to use the homeowner. Step stool to get on the counter where they recently cut open the sheet rock for a previous leak on the same pipe. Luckily, the pipe was already exposed so there was no need for a diagnostic fee to search and locate. But after I gave the home owners the price for the fix, they did not seem interested in moving forward and said that they will take care of the leak themselves. I did refer our restoration company for the water damage and told the homeowners if they changed their mind to give us a call. Thank you


Zak L.

Zak L. Job Checkin

1/10/24 Arrived for rec work Replaced both damper systems Confirmed open and close correctly UV, water safety, and surge protection recommended